Garmin G1000 Pilot’s Guide for the Hawker Beechcraft C90A/GT

190-00663-01 Rev. A

SY

STEM

O

VER

VIEW

FLIGHT

INSTRUMENTS

EIS

AUDIO P

ANEL

& CNS

FLIGHT

MANA

GEMENT

HAZARD

AV

OID

ANCE

AFCS

ADDITIONAL FEA

TURES

APPENDICES

INDEX

528

APPENDIX A

System Annunciation

Comment

GPS information is either not present or is invalid for navigation use.
Note that AHRS utilizes GPS inputs during normal operation. AHRS operation may be degraded if
GPS signals are not present (see POH).

Other Various Red X

Indications

A red ‘X’ through any other display field (such as engine instrumentation display) indicates that the
field is not receiving valid data.

G1000 SYSTEM MESSAGE ADVISORIES

This section describes various G1000 system message advisories. Certain messages are issued due to an LRU

or an LRU function failure. Such messages are normally accompanied by a corresponding red ‘X’ annunciation
as shown previously in the G1000 System Annunciation section.

NOTE:

This Section provides information regarding G1000 message advisories that may be displayed by

the system. Knowledge of the aircraft, systems, flight conditions, and other existing operational priorities
must be considered when responding to a message. Always use sound pilot judgment. The AFM/POH takes
precedence over any conflicting guidance found in this section.

MFD & PFD MESSAGE ADVISORIES

Message

Comments

DATA LOST – Pilot stored data was
lost. Recheck settings.

The pilot profile data was lost. System reverts to default pilot profile and settings. The
pilot may reconfigure the MFD & PFD with preferred settings, if desired.

XTALK ERROR – A flight display
crosstalk error has occurred.

The MFD and PFD are not communicating with each other. The G1000 system should
be serviced.

PFD1 SERVICE – PFD1 needs service.
Return unit for repair.

The PFD and/or MFD self-test has detected a problem. The G1000 system should be
serviced.

PFD2 SERVICE – PFD2 needs service.
Return unit for repair.
MFD1 SERVICE – MFD1 needs
service. Return unit for repair.
MANIFEST – PFD1 software
mismatch. Communication halted.

The PFD and/or MFD has incorrect software installed. The G1000 system should be
serviced.

MANIFEST – PFD2 software
mismatch. Communication halted.
MANIFEST – MFD1 software
mismatch. Communication halted.
PFD1 CONFIG – PFD1 configuration
error. Config service req’d.

The PFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.

PFD2 CONFIG – PFD2 configuration
error. Config service req’d.

Advertising