F4:BURST - (Burst) - Triggers output N cycles for each trigger event, where N ranges from 2 to 999,999.

F5: PHASE - Selects the start phase of the signal in non-continuous modes. The range is from -180˚ to +180˚, with a 0.1˚

resolution. In PHASE mode F2: SET-ZERO

sets the phase reference to zero when few instruments are

connected to the same external reference and need to be synchronized with different phase relations.

After selecting the TRIG , GATE or BURST menu, the trigger source menu is available:

Trigger Menu

F1: MAN - Selects manual as the trigger source. To trigger the waveform generator,

press this MAN TRIG again.

F2: INT - Selects the internal trigger generator as the trigger source. Change the

internal trigger rate displayed with the rotary input knob.

F3: EXT - Selects the external trigger signal as the trigger source. The trigger source

is supplied through the TRIG IN connector.

F4: NBRST - Selects the number of burst pulses to be output with each trigger. The N can be changed from 2 to

999,999.

F5:PREV - Goes back to previous menu

3.6.3 WAVEFORM Key

Displays the waveforms available:

Waveform Menu

F1: SINE - Selects the sine waveform.

F2: SQR - Selects the square waveform and displays the waveform duty cycle that can be changed from 20% to 80% up to 10MHz

and 40% to 60% to 30MHz.

F3: TRI - Selects the triangle waveform and displays the waveform duty cycle that can be changed from

10% to 90%. The triangle

maximum frequency is 5MHz.

Advertising
This manual is related to the following products: