64

Command Type: Setting or Query

Setting

Syntax:

[:SOURce:] PULse:RISe <ws><phase>

[:SOURce:] PULse:RISe <ws>MINimum|MAXimum

Examples:

[:SOURce:] PULse:RISe 500NS

Query

Syntax:

[:SOURce:] PULse:RISe?[<ws>MINimum|MAXimum]

Response:

NR3

4.13.1.12.5 PULse FALl

This command sets falling edge of the pulse to the specified value.

Arguments

Type:

Numeric

Units:

S, mS, uS, nS

Range:

100 nS minimum; maximum defined by period and width (see note above)

Rounding:

4 digits

Command Type: Setting or Query

Setting

Syntax:

[:SOURce:] PULse:FALl <ws><phase>

[:SOURce:] PULse:FALl <ws>MINimum|MAXimum

Examples:

[:SOURce:] PULse:FALl 500NS

Query

Syntax:

[:SOURce:] PULse:FALl?[<ws>MINimum|MAXimum]

Response:

NR3

4.13.1.13 Duty Cycle

:SOURce:DCYCle <duty cycle value>

This command is used to set the duty-cycle of the square wave or the symmetry of triangular wave. The value is given in

percent .

Arguments

Type:

Numeric

Units:

None (percent implied)

Range:

20 to 80

Rounding:

to integer

Command Type: Setting or Query

Setting

Syntax:

:SOURce:DCYCle <ws><duty cycle value>

:SOURce:DCYCle <ws>MINimum|MAXimum

Query

Syntax:

:SOURce:DCYCle?[<ws>MINimum|MAXimum]

Response:

NR3

4.13.2 OUTPut Subsystem

The Output Subsystem controls characteristics of the source's output. Included in this subsystem are the State and Summing

commands. The command structure is as follows:

:OUTPut

[:STATe] <Boolean>

:SUMming <Boolean>