Note: For model 4079, nothing changes in the commands above to control channel 1. But for channel 2, change :OUTP
to :OUTP2. For example, to change channel 2 output to ON, send the command: OUTP2 ON or OUTP2 1.
4.13.2.1 Output State
:OUTPut [:STATe] <state 0,1>
This command controls whether the output is ON or OFF.
Arguments
Type:
Boolean
Command Type: Setting or Query
Setting
Syntax:
:OUTPut[:STATe]<ws>ON|1|OFF|0
Examples:
:OUTP:STAT ON
:OUTP OFF
Query
Syntax:
:OUTPut[:STATe]?
Response:
0|1
4.13.2.2 Output Summing
:OUTPut :SUMming <state 0,1>
This command controls whether the summing is ON or OFF.
Arguments
Type:
Boolean
Command Type: Setting or Query
Setting
Syntax: :
OUTPut:SUMming<ws>ON|1|OFF|0
Examples:
:OUTP:SUM ON
:OUTP:SUM OFF
Query
Syntax:
:OUTPut:SUMming?
Response:
0|1
4.13.3 Trigger Subsystem
The Trigger Subsystem is used to control the waveform triggering. The command structure is as follows:
:TRIGger
:MODE CONTinuous|TRIGger|GATE|BURSt
:BURSt <numeric value>
:SOURce <MANual|INTernal|EXTernal|BUS
:TIMer <numeric value>
Note: For model 4079, nothing changes in the commands above to control channel 1. But for channel 2, change :TRIG
to :TRIG2. For example, to change channel 2 mode to gate, send the command: TRIG2:MODE GATE.
4.13.3.1 Trigger Mode
:TRIGger:MODE <trigger mode>