23

Protect Function. Protects (makes read-only) a section of waveform memory.

F1: FROM - Selects the address of the first point to protect.

F2: TO - Selects the address of the last point to protect.

F3: ALL - Protects the whole waveform memory. Equivalent to selecting from 1 to 4,000,000.

Note: You can protect only one segment of waveform memory at a time.

F4: ON/OFF - Selects the unprotect mode and resets memory protection so that the whole waveform

memory can be written into.

F5: PREV - Returns to previous menu.

3.6.5 PULSE Menu

From the WAVE menu, select F4:PULSE.

F1: FREQ/PERIOD - Selects the parameter definition of the Pulse repetition period.

F2: WIDTH

- Selects the Width of the generated pulse.

F3: EQUAL EDGE - Selects equal Rise (Leading edge) and Fall (Trailing edge) times of the pulse.

F4: LEAD-TRAIL - Selects different Rise and Fall times of the Pulse.

F5:PREV

- Returns to previous menu.

3.6.6 UTILITY Key

Utility Menu

F1: GPIB

- Selects the GPIB remote mode of operation. After selection the GPIB address can be set to any value

from 1 to 31 using the rotary knob. The value is kept in a nonvolatile memory and used at power-on. The

factory default address is 9. Setting the address to 31 puts the device in the off-bus state (it will not respond

to messages on the GPIB bus).

F2:RS232

- Selects the RS232 remote control mode. After selection, the baud rate can be selected as 2400, 9600,
19200, and 38400. The RS-232 uses 8 bit data, 1 stop bit and no parity.