Connection

For security reasons, users cannot just connect to the Runtime. Thus, the Communicate using port parameter allows
users to specify a TCP/IP port which the Runtime will open and then listen to for console connections.

Session Management

Users can manage the connection sessions so that resources aren't being used where they aren't needed. Descriptions
of the selections are as follows.

Maximum number of simultaneous connects: This setting is used to specify the number of Configuration
connections that can be made to the Runtime at one time. The range is 1 to 64. The default is 10.

Maximum idle seconds for writer before privilege demotion: This setting is used to the length of time of
stopped activity before the connected Configuration can no longer make changes. The range is 60 to 3600
seconds. The default is 900 seconds.

Maximum idle seconds before session timeout: This setting is used to set the length of time that the console
connection can sit idle before it times out. The range is 10 to 3600 seconds. The default is 60 seconds.

Runtime Settings - Runtime Process

The Runtime Process tab is used to specify the server Runtime's process mode, as well as how it utilizes the PC's
resources.