Standard performance, Accuracy (combined with axf remote flowtube) – Yokogawa ADMAG AXF User Manual

Page 104

Advertising
background image

IM 01E20C01-01E

11-3

11. OUTLINE

Polyurethane Rubber/Natural Soft Rubber/EPDM
Rubber Lining

Size mm (in.)

V

Ͻ 0.3 (1.0)

Ϯ1.0 mm/s

0.3

Ϲ V Ϲ 10

(1.0) (33)

Ϯ0.35% of Rate

25 (1.0)
to
400 (16)

Flow Velocity

V m/s (ft/s)

Standard Accuracy

(Calibration code B)

V

Ͻ 0.3 (1.0)

Ϯ1.75 mm/s

0.3

Ϲ V Ͻ 1

(1.0) (3.3)

1

Ϲ V Ϲ 10

(3.3) (33)

Ϯ0.35% of Rate

Ϯ0.25% of Rate Ϯ1 mm/s

500 (20)
to
1000 (40)

V

Ͻ 0.3 (1.0)

Ϯ2.2 mm/s

0.3

Ϲ V Ͻ 1

(1.0) (3.3)

Ϯ0.4% of Rate Ϯ1 mm/s

1

Ϲ V Ϲ 10

(3.3) (33)

Ϯ0.5% of Rate

1100 (44)
to
2000 (80)

V

Ͻ 1 (3.3)

Ϯ8.5 mm/s

1

Ϲ V Ϲ 10

(3.3) (33)

Ϯ0.85% of Rate

2200 (88)
to
2600 (104)

T02.EPS

Enhanced dual frequency excitation (Option code HF2) :
Standard accuracy

Ϯ 1 mm/ s

Size 25 mm (1.0 in.) to 400 mm (16 in.)

1.2

1.0

0.8

0.6

0.4

0.35

0.2

0

0

1

2

6

8

10

V[m/s]

High grade Accuracy

High grade Accuracy

Standard Accuracy

F01.EPS

Pulse
Output
Accuracy

% of Rate

Size 500 mm (20 in.) to 1000 mm (40 in.)

1.2

1.0

0.8

0.6

0.4

0.35

0.2

0

0

1

2

6

8

10

V[m/s]

F16-1.EPS

Pulse
Output
Accuracy

% of Rate

High grade Accuracy

High grade Accuracy

Standard Accuracy

Size 1100 mm (44 in.) to 2000 mm (80 in.)

1.2

1.0

0.8

0.6

0.4

0.2

0

0

1

2

6

8

10

V[m/s]

F16-2.EPS

Pulse
Output
Accuracy

% of Rate

0.5

High grade Accuracy

High grade Accuracy

Standard Accuracy

STANDARD PERFORMANCE

Accuracy (Combined with AXF Remote Flowtube)

Note: The accuracy of a product before shipment is

defined as totalized value at the result of calibration
test in our water actual flow test facility.
Calibrated conditions in our water actual test facility
are as follows:

Fluid temperature;

20

± 10°C

Ambient temperature; 20

± 5°C

Length of straight runs; 10 D or more on the

upstream side; 5 D or more
on the downstream side

Reference conditions; Similar to BS EN29104

(1993); ISO 9104 (1991)

Pulse Output:

PFA/Ceramics Lining:

Size mm

(in.)

V

Ͻ 0.3 (1)

Ϯ1.0 mm/s

Ϯ0.5 mm/s

Ϯ0.5 mm/s

0.3

Ϲ V Ϲ 10

(1) (33)

V Ͻ 0.15 (0.5)

V Ͻ 0.15 (0.5)

0.15

Ϲ V Ϲ 10

(0.5) (33)

0.15

Ϲ V Ϲ 10

(0.5) (33)

V Ͻ0.15 (0.5)

0.15

Ϲ V Ͻ1

(0.5) (3.3)

Ϯ0.35% of
Rate

Ϯ0.5 mm/s

Ϯ0.35% of
Rate

Ϯ0.35% of
Rate

2.5 (0.1)
to
15 (0.5)

250 (10)
to
400 (16)

25 (1.0)
to
200 (8.0)

Flow Velocity

V m/s (ft/s)

Flow Velocity

V m/s (ft/s)

Standard

Accuracy

(Calibration

code B)

High grade

Accuracy

(Calibration

code C)

Ϯ0.18% of Rate

Ϯ0.2mm/s

1

Ϲ V Ϲ10

(3.3) (33)

Ϯ0.2% of Rate

T01.EPS

Enhanced dual frequency excitation (Option code HF2) :
Standard accuracy

Ϯ 1 mm/ s

Size 2.5 mm (0.1 in.) to 15 mm (0.5 in.)

1.2

1.0

0.8

0.6

0.4

0.35

0.2

0

0

1

2

6

8

10

V[m/s]

High grade Accuracy

High grade Accuracy

Standard Accuracy

F01.EPS

Pulse
Output
Accuracy

% of Rate

Size 25 mm (1.0 in.) to 400 mm (16 in.)

1.2

1.0

0.8

0.6

0.4

0.35

0.2

0

0

1

2

6

8

10

V[m/s]

F02.EPS

Pulse
Output
Accuracy

% of Rate

Standard Accuracy

High grade Accuracy

Advertising