6-7

6. PARAMETER DESCRIPTION

T0607-2.EPS

Item

Name

Display unit

(BRAIN)

Data range

Display unit

/BRAIN

Default value

(*): Indicated item

Units

R/W

Position

of decimal

point

Description

F14 SO1/2 Active Mode

(SO ACT MODE)

W

Closed(On) Act
Open(Off) Act

Closed(On) Act

Selects whether SO1/SO2 output
will be set to “On Active” or
“Off Active.”

F15 SI1/2 Active Mode

(SI ACT MODE)

W

Short Active
Open Active

Short Active

Selects whether SI1/SI2 input
will be set to “Short Active” or
“Open Active.”

F30 Forward Span2

(FWD SPAN2)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for forward
No. 2 range

F31 Forward Span3

(FWD SPAN3)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for forward
No. 3 range

F32 Forward Span4

(FWD SPAN4)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for forward
No. 4 range

F33 Reverse Span1

(REV SPAN1)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for reverse
No. 1 range

F34 Reverse Span2

(REV SPAN2)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for reverse
No. 2 range

F35 Reverse Span3

(REV SPAN3)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for reverse
No. 3 range

F36 Reverse Span4

(REV SPAN4)

W

C40

/C41

0 to 4

0.0001 to 32000

1

Sets flow rate span for reverse
No. 4 range

F40 Auto Range Hys

(AUTO RNG HYS)

W

%

0

0 to 15

10 %

Sets hysteresis width for
automatic range switching

F41 Bi Direction Hys

(BI DIREC HYS)

W

%

0

0 to 8

2 %

Sets hysteresis width for
forward/reverse switching

F12 SI1 Function

(SI1 FUNCTION)

W

No Function
0% Singal Lock
Ext Auto Zero
Ext Ttl Preset
Ext Rev Ttl Set
Ext 2 Ranges
Ext 3 Ranges
Ext 4 Ranges

No Function

Selects function for the SI1
terminal

F13 SI2 Function

(SI2 FUNCTION)

W

No Function
0% Singal Lock
Ext Auto Zero
Ext Ttl Preset
Ext Rev Ttl Set
Ext 2 Ranges
Ext 3 Ranges
Ext 4 Ranges

No Function

Selects function for the SI2
terminal

See “6.5 Alarm Function”.

F60 —

(SELF CHECK)

R

Good
Error

(7) Item G (Menu G): Alarm Setting items

Menu G contains setting items relevant to alarm output, burnout, alarm record, etc.

Item

Name

Display unit

(BRAIN)

Data range

Display unit

/BRAIN

Default value

(*): Indicated item

Units

R/W

Position

of decimal

point

Description

T0608-1.EPS

G00 Alarm

(ALARM)

G10 Low Alarm

(LOW ALARM)

W

%

0

-110 to 110

-110

Sets level setting value for low
flow rate limit (L)

G11 High Alarm

(HIGH ALARM)

W

%

0

-110 to 110

110

Sets level setting value for high
flow rate limit (H)

G12 Low Low Alarm

(LO LO ALARM)

W

%

0

-110 to 110

-110

Sets level setting value for low-
low flow rate limit (LL)

G13 High High Alarm

(HI HI ALARM)

W

%

0

-110 to 110

110

Sets level setting value for high-
high flow rate limit (HH)