2 setting mode, 3 parameter setting procedure, Setting mode -5 – Yokogawa ADMAG AXF User Manual

Page 25: Parameter setting procedure -5

Advertising
background image

IM 01E20C01-01E

5-5

5. BASIC OPERATING PROCEDURES

5.2.2

Setting Mode

When the Setting Mode has been activated using the procedure from Section 5.2.1, param-
eters can be selected for setting.

NOTE

If no operations are carried out for a period of 10 minutes in Setting Mode, the
system will automatically return to the Display Mode.

Format for Parameter Data

Depending on the type of parameter, data is formatted in one of the following three ways.

B21:Base Flow Unit
m

3

m

3

kl(Kiloliter)

Format

Typical display

Content

(i) Selection-type

The desired data item is selected from a predefined list.

Data is set using the values in each digit and using
the decimal point.

Data is composed using alphanumeric characters
(in the case of tag numbers, special units, and the like).
With this format, setting can be carried out using up to
16 of the characters shown below.

(ii) Numeric-type

(iii) Alphanumeric-type

Regarding the alphanumeric-type format (iii), the following alphanumerics are displayed in the following sequence:

# % & * + - . / 0 1 2 3 4 5 6 7 8 9 : < > A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j
k l m n o p q r s t u v w x y z

[space]

B23:Flow Span
100 l/min
000100 l/min
Rng:0.00001 32000

C10:Tag No
FI-1101
FI-1201

T0502.EPS

5.3 Parameter Setting Procedure

Once the system is in Setting Mode, the parameters for setting can be selected. On the
AXFA11, parameters that are frequently used have been grouped together in Easy Setup in
Menu B. This section provides a description of the parameter setting procedure using B:
Easy Setup and C: Basic Setup
.

For more details regarding parameter content, please refer to Section 6: Parameter Descrip-
tion.

5.3.1

Setting Example for Selection-Type Data: Flow rate units

This example describes the setting of the flow rate units for the selection-type parameter
B21: Base Flow Unit from m

3

to l (Liter).

Major Item Parameter Search Mode has been
accessed in this screen.

Touch the

switch to access B: Easy Setup.

NOTE

The

᭡ and ᭢ symbols to the left of the param-

eters indicate that additional setting items to

those being currently displayed may also be

selected. Use the

switch to cycle

through these items.

Setting Mode

P:Protect

B:Easy Setup

C:Basic Setup

F0504-1.EPS

Setting Mode

Major item
parameter

Start:

Major Item

Parameter

Search Mode