1 operating panel configuration and functions, Operating panel configuration and functions -2 – Yokogawa ADMAG AXF User Manual

Page 22

Advertising
background image

IM 01E20C01-01E

5-2

5. BASIC OPERATING PROCEDURES

5.1 Operating Panel Configuration and Functions

(1) Data display area

1st line (Display Select1), 2nd line (Display
Select2), and 3rd line (Display Select3) can be
displayed using parameter settings. The content
corresponding to selected item is shown with the
reversed-character on the right of the line.

(2) Setting switch operations

: Move the layer down, select, and confirm

+

: Move the layer up

(Press the

switch while

holding down the

switch)

: Move the cursor down (for selection-type

parameters) or increase values (for nu-
meric-type parameters)

: Move the cursor to the right (for numeric-

type parameters)

+

: Move the cursor up (for selec-

tion-type parameters)

(3) Display items

Displayed items and

reversed-character indication

T0501.EPS

Displays the instantaneous flow rate for the span as a percentage.

Displays the actual reading for instantaneous flow rate.

Displays the instantaneous flow rate for the span as a current output value.

Displays the instantaneous flow rate for the span as a percentage
using bar graph.

Displays the totalized value for flow rate in the forward direction.

Displays the totalized value for flow rate in the reverse direction.

Displays the differential totalized value for flow rate between
forward totalization and reverse totalization.

Display the tag number (using up to 16 characters).

Displays the adhesion condition in the form of a bar graph.
(See the description for parameters K10 through K15 from
Chapter 6: Parameter Description for more details.)

Displays the communication type.

Content

Disp Select1

Disp Select2
Disp Select3

Instantaneous flow rate: %

Actual instantaneous flow rate

Instantaneous flow rate: mA

Bar graph indicating
instantaneous flow rate

Totalized forward-direction flow rate

Totalized reverse-direction flow rate

Totalized differential flow rate

Tag number

Diagnosis of electrode adhesion

Communication type

FR

FR

FR

None

FTL

RTL

DTL

TAG

ADH

COM

(4)

F0501.EPS

(4)

Reversed character display

(3) Display items

(2) Setting switches

(1) Data display area

(Infra-red switches)

FR

m

3

/h

: : :

100

3274m

3

FTL

0

Advertising