<7. Operation>

7-4

IM 01C27B01-01EN

F0705.ai

within 30cm

Figure 7.5

Provisioning Example

■ Provisioning work
This subsection describes provisioning work using

FieldMate as the provisioning device.

Provisioning work performs provisioning for each

field wireless device using FieldMate and an

infrared adapter. If Yokogawa - recommended

infrared device is used for provisioning, distance

between the transmitter glass window and the

infrared device should be within 30cm. For details of

Yokogawa - recommended infrared device, refer to

subsection 9.2 “Calibration Instruments Selection”.

Perform the following provisioning tasks.

• Setting provisioning information

• Creating a provisioning information file

1) Setting provisioning information

Set the device tag and network ID using a

FieldMate provisioning function. The device

tag, network ID, and join key are set in the Field

Wireless Device. It is not necessary to input

a join key because FieldMate automatically

generates it.

Setting device tag

The device tag is used for the user to

recognize the Field Wireless Device.

Setting network ID

This is the network ID for the field wireless

network to which the field wireless device is

connected. Set a value from 2 to 65535.

The field wireless device is connected to the

field wireless network corresponding to the

network ID set by provisioning work.

2) Creating a provisioning information file

The following provisioned information is stored

in the provisioning information file.

• Network ID

• Device tag

• EUI64

• Join key

• Provisioner (name of the user who performed

provisioning work by FieldMate)

• Date (Time and date when provisioning was

performed by FieldMate)

This provisioning information file is required to

load from the Field Wireless Configurator to the

Field Wireless Integrated Gateway. Store the

file carefully.

■ Connecting to a field wireless network
The action after installing the battery pack varies

depending on the silence setting.

Mounting the battery pack automatically starts a

search for the field wireless network. When the

Field Wireless Integrated Gateway is found, the

instrument enters the join status.

When the field wireless gateway is not found and

a specified time based on the silence mode has

elapsed, a cycle of a one-hour pause and six-

minutes search is repeated until the instrument can

join the field wireless network.

For details on the procedure to switch to silence

mode, refer to subsection 8.3.17 “Switching to

Silence Mode.”

F0706.ai

Mounting battery pack

Boot

Infrared communication

Pause (b)

Search failure for

the specified time

Infrared

communication

1 hour

passed

Search failure

for 6 minutes

Ready 2:

Searching (b)

(Connect)

(Connect)

Confirm connecting

status: Join (c)

(Publish)

Operation (d)

Deep sleep

setting

(Disconnect)

(Disconnect)

Ready 1:

Searching (b)

Deep sleep (a)

Infrared

communication

Figure 7.6

Wireless Connection Process