<9. Maintenance>

9-5

IM 01C27B01-01EN

3) Align and engage the zero-adjustment screw

pin with the groove on the bracket on the CPU

assembly. Then insert the CPU assembly

straight onto the post in the amplifier case.

4) Tighten the two bosses. Mount the RF

assembly, and the integral indicator (refer to

subsections 9.4.1 and 9.4.2).

IMPORTANT

Confirm that the zero-adjustment screw pin is

placed properly in the groove on the bracket prior

to tightening the two bosses. If it is not, the zero-

adjustment mechanism will be damaged.

5) Replace the cover.

9.4.4 Cleaning and Replacing the Capsule

Assembly

CAUTION

Precautions for the intrinsic safety explosion

prevention type instrument

Modification is not permitted by the user for

intrinsic safety explosion prevention type

transmitter. Consult our company when you want

to exchange capsule assembly.

Execute it only at time when the following points

were confirmed for exchange capsule assembly

in the same range of measurement.

• Exchanged capsule assembly uses the one

of the same specification.

• Tighten Setscrew to fix the transmitter

section and the pressure detector section

surely after ending maintenance.

This subsection describes the procedures for

cleaning and replacing the capsule assembly. (See

figure 9.3.)

■ Removing the Capsule Assembly

IMPORTANT

Exercise care as follows when cleaning the

capsule assembly.

• Handle the capsule assembly with care, and

be especially careful not to damage or distort

the diaphragms that contact the process

fluid.

• Do not use a chlorinated or acidic solution for

cleaning.

• Rinse with clean water after cleaning, please

dry until completely dry.

1) Remove the CPU assembly as shown in

subsection 9.4.3.

2) Remove the five setscrews, the stopper bolt,

and the stopper that connect the transmitter

section and pressure-detector section.

3) Remove the hexagon-head screw and the

stopper.

4) Separate the transmitter section and pressure-

detector section.

5) Remove the nuts from the four flange bolts.

6) While supporting the capsule assembly with

one hand, remove the cover flange.

7) Remove the capsule assembly.

8) Clean the capsule assembly or replace with a

new one.

■ Reassembling the Capsule Assembly
1) Insert the capsule assembly between the flange

bolts, paying close attention to the relative

positions of the H (high pressure side) and

L (low pressure side) marks on the capsule

assembly.

Replace the two capsule gaskets with new

gaskets.

2) Install the cover flange on the high pressure

side, and use a torque wrench to tighten the

four nuts uniformly to a torque shown below.

Model

EJX110B, EJX310B, EJX430B

Wetted parts material code

S (except for

Measurement

span code F)

H,M,T,A,D,B or

S (Measurement

span code F)

Torque(N·m)

{kgf·m}

17

{1.7}

40

{4.1}