2 model and suffix codes, Model and suffix codes -4 – Yokogawa EJX430B User Manual

Page 95

Advertising
background image

<11. General Specifications>

11-4

IM 01C27B01-01EN

11.2 Model and Suffix Codes

Model EJX110B

Model

Suffix Codes

Description

EJX110B

. . . . . . . . . . . . . . . . . . . . . . Differential pressure transmitter

Output signal

-L . . . . . . . . . . . . . . . . . . . .

Wireless communication (ISA100.11a protocol)

Measurement

span (capsule)

F . . . . . . . . . . . . . . . . . . .

L . . . . . . . . . . . . . . . . . . .

M . . . . . . . . . . . . . . . . . .

H. . . . . . . . . . . . . . . . . . .

V. . . . . . . . . . . . . . . . . . .

0.1 to 5 kPa (0.4 to 20 inH

2

O) (For wetted parts material code S)

0.1 to 10 kPa (0.4 to 40 inH

2

O) (For wetted parts material code M, H, T, A,

D and B)

0.5 to 100 kPa (2 to 400 inH

2

O)

2.5 to 500 kPa (10 to 2000 inH

2

O)

0.07 to 14 MPa (10 to 2000 psi)

Wetted parts

material

*1

. . . . . . . . . . . . . . . . . Refer to “Wetted Parts Materials” Table 1.

Process connections

0 . . . . . . . . . . . . . . . .

1 . . . . . . . . . . . . . . . .

2 . . . . . . . . . . . . . . . .

3 . . . . . . . . . . . . . . . .

4 . . . . . . . . . . . . . . . .

5 . . . . . . . . . . . . . . . .

without process connector (Rc1/4 female on the cover flanges)

with Rc1/4 female process connector

with Rc1/2 female process connector

with 1/4 NPT female process connector

with 1/2 NPT female process connector

without process connector (1/4 NPT female on the cover flanges)

Bolts and nuts material

J . . . . . . . . . . . . . .

G. . . . . . . . . . . . . .

C. . . . . . . . . . . . . .

ASTM-B7 carbon steel

316L SST stainless steel

ASTM grade 660 stainless steel

Installation

-7 . . . . . . . . . . .

-8 . . . . . . . . . . .

-9 . . . . . . . . . . .

-B . . . . . . . . . . .

-U . . . . . . . . . . .

Vertical piping, left side high pressure, and process connection downside

Horizontal piping and right side high pressure

Horizontal piping and left side high pressure

Bottom Process Connection, left side high pressure

*2

Universal flange

*2

Amplifier housing

7 . . . . . . . . . .

8 . . . . . . . . . .

9 . . . . . . . . . .

Cast aluminum alloy with integral antenna

Cast aluminum alloy with detachable antenna (2 dBi)

*4

Cast aluminum alloy without antenna (N connector)

*3*4

Electrical connection

J . . . . . . . . . No electrical connection, battery-powered type (battery case only; battery

cells not included)

Integral indicator

D. . . . . . .

Digital indicator

Mounting bracket

B. . . . .

D. . . . .

G. . . . .

K. . . . .

M . . . .

N. . . . .

304 SST 2-inch pipe mounting, flat type (for horizontal piping)

304 SST 2-inch pipe mounting, L type (for vertical piping)

304 SST 2-inch pipe mounting (for bottom process connection type)

316 SST 2-inch pipe mounting, L type (for vertical piping)

316 SST 2-inch pipe mounting (for bottom process connection type)

None

Optional codes

/  Optional specification

The “►” marks indicate the most typical selection for each specification.

*1:

!

Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of

inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant

facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid

can contaminate the user’s process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,

and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*2:

Applicable for wetted parts material code S.

*3:

Order the antenna separately from accessary option.

*4:

Remote antenna cables can be attached. Order separately from accessary option.

Advertising