<11. General Specifications>

11-3

IM 01C27B01-01EN

Minimum Pressure Limit:

See graph below
EJX110B and EJX430B

Atmospheric

pressure

-40

(-40)

0

(32)

40

(104)

80

(176)

120

(248)

1(0.14)

2.7(0.38)

10(1.4)

(psi abs)

100(14.5)

Process temperature °C (°F)

Working

pressure

kPa abs

Applicable range

F01.ai

EJX310B

-40

(-40)

0

(32)

40

(104)

80

(176)

120 (248)

0.1(0.75)

0.13(1)

1(7.5)

100(750)

10(75)

2.7(20)

0.46

(3.45)

0.01(0.075)

0.013(0.1)

85

(185)

(mmHg abs)

Working

pressure

kPa abs

Process temperature °C (°F)

M,A and B capsule

L capsule

F02.ai

Applicable range

Figure 1. Working pressure and Process Temperature