2 csa certification, Csa certification -5 – Yokogawa EJX530B User Manual

Page 13

Advertising
background image

<2. Handling Cautions>

2-5

IM 01C27F01-01EN

Note 2. Installation

• Installation should be in accordance with

ANSI/ISA-RP12.06.01 and the National

Electric Code (NFPA 70).

• Dust-tight conduit seal must be used when

installed in a Class II, III, Group E, F and G

environments.

• Note a warning label worded

“SUBSTITUTION OF COMPONENTS MAY

IMPAIR INTRINSIC SAFETY,” and “INSTALL

IN ACCORDANCE WITH DOC. NO.

IFM037-A20”.

Transmitter

[Intrinsically Safe]

Class I, II, III, Division 1,

Groups A,B,C,D,E,F,G

Class I, Zone 0

in Hazardous (Classified)

Locations

AEx ia IIC

[Nonincendive]

Class I, II, Division 2,

Groups A,B,C,D,F,G

Class III, Division 1.

Class I, Zone 2, Group IIC,

in Hazardous (Classified)

Locations

Battery Pack

[Installation Diagram]

Amplifier housing code 7

Hazardous Location

F0210.ai

Transmitter

[Intrinsically Safe]

Class I, II, III, Division 1,

Groups A,B,C,D,E,F,G

Class I, Zone 0

in Hazardous (Classified)

Locations

AEx ia IIC

[Nonincendive]

Class I, II, Division 2,

Groups A,B,C,D,F,G

Class III, Division 1.

Class I, Zone 2, Group IIC,

in Hazardous (Classified)

Locations

Antenna

(*1)

Arrester

(*1, *2)

*1: These apparatus are simple apparatus.

*2: Arrester may not be connected.

Antenna Connector

Battery Pack

Amplifier housing codes other than 7

Hazardous Location

Note 3. Maintenance and Repair

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void FM

Approvals approval.

Note 4. Battery Pack

USE ONLY BATTERY PACK YOKOGAWA

F9915MA OR F9915NS.

Note 5. Special Conditions for safe use

POTENTIAL ELECTROSTATIC CHARGING

HAZARD-SECURE DISTANCE OF 100MM

FROM ANTENNA.

DO NOT OPEN WHEN CL II, III, DIV 1,2

ATMOSPHERE IS PRESENT.

2.8.2 CSA Certification

Caution for CSA Intrinsically safe type. (Following

contents refer to “DOC No. ICS030”)
Note 1. Model EJX Series differential, gauge,

and absolute pressure transmitters with

optional code /CS17 are applicable for use

in hazardous locations

Certificate: 2325443

• Applicable standard: CAN/CSA-C22.2 No.0,

CAN/CSA-C22.2 No.0.4, C22.2 No.25,

CAN/CSA-C22.2 No.94,

CAN/CSA-C22.2 No.157, C22.2 No.213,

CAN/CSA-C22.2 No.61010-1,

CAN/CSA- C22.2 No.60079-0,

CAN/CSA-E60079-11, IEC60529

• Ex ia IIC T4

• Intrinsically Safe for Class I, Division 1,

Groups A, B, C & D, Class II, Division 1,

Groups E, F & G, Class III, Division 1

• Nonincendive for Class I, Division2,

Groups A, B, C & D, Class II, Division2,

Groups F & G, Class III, Division1

• Enclosure: IP66/IP67 and Type 4X

• Temperature Code: T4

• Ambient Temperature: –50 to 70°C

• Max. Process Temp.: 120°C

Note 2. Installation

• Installation should be in accordance with

Canadian Electrical Code Part I and Local

Electrical Code.

• Do not alter drawing without authorization

from CSA.

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void

Canadian Standards Intrinsically safe and

nonincendive Certification.

Advertising
This manual is related to the following products: