Yokogawa EJX530B User Manual

Page 77

Advertising
background image

<10. Parameter Summary>

10-2

IM 01C27F01-01EN

Object

ID

Attribute

ID

Label

Description

Default

value

Handling

1.

UAPMO

block

(continued)

104

Reset Energy Left

Initialize the remaining battery life (Energy Left) and

reset it as new batteries.

Perform the battery replacement.

0 = Continue (Cancel)

1 = Reset (Initialization)

0 (reading value

is always 0)

W

105

Power Supply

Status

Indicates the predicted battery level and the power

supply method.

0 = external power supply

1 = battery level 75% or more

2 = battery level 25% ~ 75%

3 = battery level 25% or less

R

106

EHType

*2

Available to write note into this parameter.

---

W

107

Power Supply

Voltage

*2

Indicates the measured power supply voltage (V).

---

R

110

Hardware Write

Protect

Allows recognizing the status of the hardware write

protection switch.

(Switch Off, Switch On)

R

111

Radio Silence

Repeats a cycle of a 1-hour pause and 6-minute

search if the instrument cannot join the network after a

time specified in Radio Silence has elapsed.

When 0 is set, the Radio Silence is invalid.

28800

W

112

Simulation Active

Alert

*2

The On/Off or priority for Simulation Active Alert can

be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

113

Soft Update

incomplete Alert

*2

The On/Off or priority for Soft Update incomplete Alert

can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

Not available for EJX.

1. TRUE

2. 15

W

114

Power low Alert

*2

The On/Off or priority for Power low Alert can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

115

Power Critical low

Alert

*2

The On/Off or priority for Power Critical low Alert can

be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

116

Fault prediction

Alert

*2

The On/Off or priority for Fault prediction Alert can be

set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

Not available for EJX.

1. TRUE

2. 15

W

117

Environmental

conditions Alert

*2

The On/Off or priority for Environmental conditions

Alert can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

118

Outside sensor

limits Alert

*2

The On/Off or priority for Outside sensor limits Alert

can be set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

119

Out of service

Alert

*2

The On/Off or priority for Out of service Alert can be

set.

1. On/Off setting

0 = FALSE, 255 =TRUE

2. Alert report priority: 0 to 15

1. TRUE

2. 15

W

Advertising
This manual is related to the following products: