C - e – Triton FT7000XP User Manual User Manual

Page 211

Advertising
background image

C-3

A

PPENDIX

C - E

LECTRONIC

L

OCK

P

ROGRAMMABLE

F

EATURES

The locks are initially set with the standard features (a single 6-digit code). Based on your requirements,
additional features may be added in the lock, BUT THEY MUST BE PRE-PROGRAMMED by Triton prior
to shipment of the unit. The programmable features are listed below.

Manager (Factory set to 1-2-3-4-5-6):
Add/remove second user
Enable/disable second user

Dual Code:
Two (2) combinations required to open.

Silent Signal Alarm (Optional alarm box required):
Duress signal if last number of code(s) is entered
using one (1) number higher or one (1) number lower.

Time Delay:
Delay period 1-99 minutes.
Open period 1-19 minutes

Time Delay Override:
Ability to add second combination to override delay
period

Disable Lock (Optional alarm box required):
Input signal disables opening of lock by valid code

If your lock(s) have some of these features programmed in the lock, the following describe the operations
of each:

A

DD

U

SER

(If Manager, Time Delay Override, Remote Override, or Dual Combination feature programmed)

- Always perform this operation with the door(s) open!
1.

Enter Manager Code and HOLD DOWN LAST DIGIT OF CODE until the lock signals with two (2) sets
of double beeps.

2.

PRESS 1. Lock signals twice. Lock will only signal twice if the User code is not already in use. It will
beep once if a User is already installed and three (3) times if the function has not been programmed in
the lock.

3.

Enter User code twice. The lock signals twice after each valid entry.

4.

If a mistake is made, wait thirty (30) seconds and repeat steps 1 through 3.

Valid Code Entry - Double signal after valid six (6) digit code is entered.
Invalid Code Entry - Triple signal and old code is still valid.

D

ISABLE

U

SER

(Manager feature only)

- Always perform this operation with the door(s) open!
1.

Enter Manager Code and HOLD DOWN LAST DIGIT OF CODE until the lock signals with two (2) sets
of double beeps.

2.

PRESS 2. Lock signals once. User is now temporarily disabled.

3.

If a mistake is made, wait thirty (30) seconds and repeat steps 1 and 2.

Advertising