Ft7000 – Triton FT7000XP User Manual User Manual
Page 38
28
M
ODEL
FT7000
XP
U
SER
M
ANUAL
1.
NMD-100 only. Verify the cassettes are <Locked> in the dispenser.
2.
In Management Functions, select D
IAGNOSTICS
, then C
ASH
D
ISPENSER
.
3.
Select the T
EST
D
ISPENSE
option. Enter # of notes to be dispensed (1-5) from the individual cassettes
that are installed (“A”, “B”, “C”,or “D”). Select P
ERFORM
T
EST
. The Test Dispense operation will start.
4.
The Test Dispense command instructs the dispenser to dispense, minimum, one note from each
installed and operational cassette into the reject cassette. This test exercises the dispenser without
sending notes to the exit.
5.
After completion of the Test Dispense, the following prompt is displayed (Figure 3-29).
Figure 3-28. Enter # of notes.
Figure 3-29. Test dispense prompt.
V
ERIFY
O
PERATION