C-5

A

PPENDIX

C - E

LECTRONIC

L

OCK

B

ATTERY

L

OW

W

ARNING

Repeated beeping during an opening indicates that the battery is low and needs to be replaced. Recommend
replacement of battery at least once annually. The battery box is located on the inside of the door.
Note: If the lock will not operate (i.e. repeated beeping or no beeping) while the door is closed and locked, the
battery must be energized from the two external terminals on the front of the push-button panel.

To energize the lock, connect a 9-volt alkaline battery on the external terminal points. Maintain contact, enter
a valid combination, and turn the dial clockwise to open the lock.
Note: You must maintain battery contact at all times throughout this procedure.

T

IME

D

ELAY

(if feature is programmed)

- Always perform this operation with the door(s) open!
1.

Enter valid code.

Delay period starts (1-99 minutes pre-programmed).

LED flashes RED at one (1) second intervals.
- If valid code entered during delay, Delay period restarts.
- If invalid code(s) entered during delay, Delay period aborts.

2.

At end of delay period, Open period starts (1-19 minutes pre-programmed).

LED flashes RED at 1/2 second intervals.

Lock beeps at ten (10) second intervals

3.

During Open period, enter valid code(s).

If invalid code entered during open, Open period continues.

If four (4) consecutive invalid codes entered, WRONG TRY PENALTY starts.

T

IME

D

ELAY

O

VERRIDE

(if feature is programmed)

- Always perform this operation with the door(s) open!
1.

Must add second code (See ADD USER).

Second user CAN NOT be Disabled or Removed.

2.

Entry of Overide coce during Delay period will open lock.

Advertising