Optichill freecool active cabinet exhaust chillers, Sound data, Regular quiet (r) models 2 row coil – Airedale OptiChill FreeCool 500kW - 1365kW User Manual

Page 102: Chillers

Advertising
background image




OptiChill Freecool


Active Cabinet Exhaust

Chillers

102

Chillers

Technical Manual : 7197700 v1.2.0. 02_2013

Sound Data

Regular Quiet (R) Models 2 Row Coil

Sound
Measurement

Overall

dB(A)

Frequency (Hz) dB

63

125

250

500

1000

2000

4000

8000

OFC076R16-66HS1

Power

102

98

93

96

102

98

86

78

67

Pressure

@ 10m

68

64

60

63

69

64

52

45

34

OFC076R16-66MS1

Power

102

98

93

96

102

98

86

78

67

Pressure

@ 10m

68

64

60

63

69

64

52

45

34

OFC081R16-76MS2

Power

102

98

93

97

103

98

86

78

67

Pressure

@ 10m

69

64

59

63

69

64

52

44

34

OFC081R16-76ML2

Power

102

98

93

97

103

98

86

78

67

Pressure

@ 10m

69

64

59

63

69

64

52

44

34

OFC087R16-77ML2

Power

103

98

93

97

104

98

86

78

67

Pressure

@ 10m

69

64

59

63

70

64

53

44

34

OFC077R18-66HS1

Power

102

98

94

96

102

98

86

78

68

Pressure

@ 10m

68

65

60

63

69

64

52

45

34

OFC083R18-76ML2

Power

102

98

94

97

103

98

86

78

68

Pressure

@ 10m

69

65

60

63

69

64

53

44

34

OFC091R18-87HS4

Power

103

98

93

98

105

97

87

77

68

Pressure

@ 10m

70

65

60

65

71

63

53

44

34

OFC095R18-88MS4

Power

104

98

93

99

106

96

87

77

68

Pressure

@ 10m

70

65

59

65

72

63

53

43

34

OFC107R18-99HL5

Power

103

98

93

98

104

98

87

78

68

Pressure

@ 10m

69

65

60

65

70

64

53

44

34

OFC078R20-66ML1

Power

102

99

94

97

103

98

87

79

68

Pressure

@ 10m

68

65

60

63

69

64

53

45

34

OFC084R20-76HL2

Power

103

99

94

97

103

98

87

78

68

Pressure

@ 10m

69

65

60

63

69

64

53

45

34

OFC092R20-87MS4

Power

103

99

94

99

105

97

87

78

68

Pressure

@ 10m

70

65

60

65

71

63

53

44

34

OFC099R20-88HS6

Power

104

99

94

99

106

97

87

77

68

Pressure

@ 10m

70

65

60

65

72

63

53

43

34

OFC108R20-99HL6

Power

103

99

94

99

104

98

87

78

68

Pressure

@ 10m

69

65

60

65

70

64

53

44

34

OFC078R22-66MS1

Power

102

99

94

97

103

98

87

79

69

Pressure

@ 10m

68

65

60

63

69

64

53

45

34

OFC084R22-76MS2

Power

103

99

94

97

103

98

87

79

69

Pressure

@ 10m

69

65

60

63

69

64

53

45

34

OFC093R22-87HS4

Power

104

99

94

99

105

97

87

78

68

Pressure

@ 10m

69

65

60

65

71

63

53

44

34

OFC097R22-88MS4

Power

104

99

94

100

106

97

88

77

68

Pressure

@ 10m

70

65

60

65

72

63

53

43

34

OFC081R16-76ML2

Power

103

99

94

99

104

98

88

79

68

Pressure

@ 10m

69

65

60

65

70

64

53

45

34

1

dB(A) is the overall sound level, measured on the A scale.

2

All sound data measured at nominal conditions: Water in/out 15/10°C at 35°C ambient.

3

Based on standard unit, for units fitted with optional extras, please contact Airedale.

The Sound Pressure data quoted is only valid in free field conditions, where the unit is installed on a reflective base. If the equipment is
placed adjacent to a reflective wall, values may vary to those stated, typically increasing by 3dB for each side added.

Advertising