Optichill freecool active cabinet exhaust chillers, Chillers, Electrical data regular quiet continued – Airedale OptiChill FreeCool 500kW - 1365kW User Manual

Page 78

Advertising
background image




OptiChill Freecool


Active Cabinet Exhaust

Chillers

78

Chillers

Technical Manual : 7197700 v1.2.0. 02_2013

Electrical Data Regular Quiet Continued

13

14

15

Notes

Units

OFC092R20-87MS4

OFC099R20-88HS6

OFC108R20-99HL6

Unit Data

Nominal Run Amps (1)

A

533

577

618

Maximum Start Amps

A

878

1136

1157

Recommended Mains Fuse Size

A

670

710

750

Mains Supply

VAC

400 V 3 PH 50 Hz

400 V 3 PH 50 Hz

400 V 3 PH 50 Hz

Max Mains Incoming Cable Size

mm²

Direct to Bus Bar

Direct to Bus Bar

Direct to Bus Bar

Recommended Permanent Fuse Size

A

16

16

16

Permanent Supply

VAC

230 V 1 PH 50 Hz

230 V 1 PH 50 Hz

230 V 1 PH 50 Hz

Max Permanent Incoming Cable Size

mm²

4 mm² terminals

4 mm² terminals

4 mm² terminals

Control Circuit

VAC

24V/230VAC

24V/230VAC

24V/230VAC

Evaporator

Trace Heater Rating

W

250

250

250

External Trace Heating

Available (fitted by others)

W

500

500

500

Condenser Fan - Per Fan (AC)

Quantity

20

20

20

Full Load Amps

A

4.3

4.3

4.3

Locked Rotor Amps

A

15

15

15

Motor Rating

kW

2

2

2

Condenser Fan - Per Fan (EC)

Quantity

20

20

20

Full Load Amps

A

3.9

3.9

3.9

Locked Rotor Amps

A

N/A

N/A

N/A

Motor Rating

kW

2.56

2.56

2.56

Condenser Fan - Per Fan (HAEC)

Quantity

20

20

20

Full Load Amps

A

4.5

4.5

4.5

Locked Rotor Amps

A

N/A

N/A

N/A

Motor Rating

kW

2.86

2.86

2.86

Compressor - Per Compressor

Quantity

1 + 1

1 + 1

1 + 1

Nominal Run Amps

A

241.3 / 205.5

245.4 / 245.4

266.2 / 266.2

Motor Rating

kW

139.5 / 122.5

138.8 / 138.8

152.7 / 152.7

Sump Heater Rating

W

300

300

300

Start Amps (2)

A

586 / 465

805 / 805

805 / 805

Type Of Start

Star - Delta

Star - Delta

Star - Delta

OPTIONAL EXTRAS

Low Ambient Kit

Recommended Permanent Fuse Size

A

32

32

32

Permanent Supply

VAC

230 V 1 PH 50 Hz

230 V 1 PH 50 Hz

230 V 1 PH 50 Hz

Max Permanent Incoming Cable Size

mm²

4 mm² terminals

4 mm² terminals

4 mm² terminals

Power Factor Correction

Unit Nominal Run Amps (1)

A

484

508

550

Maximum Start Amps

A

858

1102

1123

Compressor Nominal Run Amps

A

211.9 / 186.1

210.9 / 210.9

232.0 / 232.0

Recommended Mains Fuse Size

A

670

710

750

Standard Head Pump (Single or Run/Standby)

Unit Nominal Run Amps

A

568

605

640

Recommended Mains Fuse Size

A

710

750

800

Pump Full Load Amps

A

35

28.5

21.2

Motor Rating

kW

18.5

15

11

Larger Head Pump (Single or Run/Standby)

Unit Nominal Run Amps

A

574

612

647

Recommended Mains Fuse Size

A

710

750

800

Pump Full Load Amps

A

41.5

35

28.5

Motor Rating

kW

22

18.5

15

Standard Head Inverter Pump (Single or Run/Standby)

Unit Nominal Run Amps

A

568

605

640

Recommended Mains Fuse Size

A

710

750

800

Pump Full Load Amps

A

35

28.5

21.2

Motor Rating

kW

18.5

15

11

Larger Head Inverter Pump (Single or Run/Standby)

Unit Nominal Run Amps

A

574

612

647

Recommended Mains Fuse Size

A

710

750

800

Pump Full Load Amps

A

41.5

35

28.5

Motor Rating

kW

22

18.5

15

(1) Based at 5.0 Evaporating, 50 Condensing, AC Standard Fans.

(2) Starting amps refers to the Star (

Ү) connection only.