NORD Drivesystems BU0510 User Manual

Page 27

Advertising
background image

3 Description of function

BU 0510 GB-3911

Subject to technical alterations

27

3.2.4

Positioning with absolute / incremental encoders in absolute mode

The encoder used for positioning is activated via parameter P604 "Encoder Type". Here, a differentiation is
made between normal measurement (for "linear" systems) and "path optimised" measurement (for circulating
systems).

Encoder type

Standard

distance

measurement

Path optimised

measurement

IG

Incremental

0

3

Incremental + save position

2

4

AG

CANopen absolute (with automatic configuration)*

1

5

CANopen absolute, manual (with manual configuration)

6

7

SSI

SK 540E and above

8

9

BISS

SK 540E and above

10

11

Hiperface

SK 540E and above

12

13

Endat 2.1

SK 540E and above

14

15

* Only CANopen encoders approved by NORD may be used with automatic configuration

Table 15: - P604 Selection of encoder type

In the function "Optimum Path" the multi-turn resolution of the encoder can be additionally limited for the
overflow point via parameter P615 "Maximum Position". The multiturn resolution in rotations (1 rotation =
1,000 rev) is entered in parameter P615. It is also possible to enter a non-integer value of rotations (for
example see Section 3.2.4.2).

After the setting or selection of the encoder type in parameter P604 "Distance measuring system" the function
of the encoder can be tested via parameter P601 "Actual Position".