POSICON position control for NORD frequency inverters, SK 530E and above

44

Subject to technical alterations

BU 0510 GB-3911

Value Function

Description

Signal*

20

Referenz

Reference point is available / has been saved

High

21

Position reached

Setpoint position has been reached

High

22

Comparative position

Position value in P626 has been reached

High

23

Comparative position
value

Position value in P262 without consideration of sign has been reached

High

24

Position array value

A value set in P613 has been reached or exceeded.

High

25

Comparative position
reached

Comparative position has been reached, as for 22 with consideration of
P625

High

26

Comparative position
value reached

Comparative position value has been reached, as for 23 with
consideration of P625

High

27

Drive in synchronous
operation

The slave drive has completed the start phase of the "Flying Saw"
function and is now synchronised with the master axis.

High

* For relay contacts (High = "Contact closed", Low = "Contact open")

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter set

P441

Relay 2 function

(Function of output 2 (Relay 2

– MFR1))

up to SK 535E

P

0 ... 39

{ 7 }

Control terminals 3/4: Functions are identical to P434!

P450

Relay 3 function

(Function of output 3 (DOUT1)

)

From SK 520E

to SK 535E

P

0 ... 39

{ 0 }

Control terminals 5/40: Functions are identical to P434! Digital output, 15V against DGND (for
SK 5x5E devices, deviations of the signal level are possible (see BU0500)).

P455

Relay 4 function

(Function of output 4 (DOUT2))

From SK 520E

to SK 535E

P

0 ... 39

{ 0 }

Functions are identical to P434! Digital output, 15V against DGND (for SK 5x5E devices,
deviations of the signal level are possible (see BU0500)).