NORD Drivesystems BU0510 User Manual

Page 71

Advertising
background image

7 Troubleshooting

BU 0510 GB-3911

Subject to technical alterations

71

Display

in the ControlBox

Fault

Text in the ParameterBox

Cause

Remedy

Group

Details in
P700 / P701

14.5

Pos. diff. Speed

Change of position and speed do not match

Check the position detection and the control setting in
P630

14.6

Diff. between Abs. and Inc.

Difference between absolute and incremental encoders

Check the position detection and the control setting in
P631

Position change for the absolute and incremental
encoders do not match

14.7

Max. Pos. Exceeded

Maximum position exceeded

Check the specified setpoint and the control setting in
P615

14.8

Min. Pos. Undershot

Minimum position undershot

Check the specified setpoint and the control setting in
P615

E025

25.0

Hiper. abs./inc. error

Hiperface encoder monitoring detects an error during
comparison of data between the incremental and absolute
signals. (absolute position deviates from that which is
calculated incrementally)

Poor cable shielding

The Sin/Cos signals are not connected or are
defective. Check with P709[-09] and [-10]

25.1

Universal encoder
communication

Communication error for the universal encoder interface (CRC
checksum error)

Poor cable shielding

Encoder triggering incorrectly set. (BISS, SSI)

SSI does not support Multiply Transmit

25.2

No corresp. universal
encoder

No connection to selected universal encoder

Encoder not connected or data cable not connected
correctly

No voltage supply to encoder

Incorrect encoder type set

25.3

Universal encoder resolution The set universal encoder resolution does not match that

which is transmitted by the encoder.

25.4

Universal encoder error

The universal encoder reports an internal error to the the FI

Restart encoder

NOTE

Parameter P650[-03] counts the communication errors to the universal encoder since switch-
on. If this parameter has a high value, this may indicate a poorly shielded encoder cable. This
may also be the cause of the error.

A communication error does not necessarily result in a fault. An error is only triggered if
several consecutive communications have failed.

Advertising