background image

4

Parameter settings

BU 0510 GB-3911

Subject to technical alterations

49

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter set

P546

[-01]

...

[-05]

Func. Bus-setpoint

(Function of bus setpoint)

SK 540E and

above

S

P

0 ... 57

{ [-01] = 1 }

alle anderen { 0 }

In this parameter, during bus actuation a function is allocated to the setpoint provided.

NOTE:

The setpoints 4 and 5 must be supported by the relevant bus module. Further
details can be found in the respective BUS operating instructions or in the
description of P400.

[-01] = Bus setpoint 1

[-02] = Bus setpoint 2

[-03] = Bus setpoint 3

[-04] = Bus setpoint 4

[-05] = Bus setpoint 5

(Illustration of functions relevant to POSICON)

17 = BusIO In Bits 0-7

21 = Setpoint position

Low word

22 = Setpoint position

High word

23 = Setpoint position,

increment Low word

24 = Setpoint position,

increment High word

47 = Gearing ratio

49 = Ramp time*

56 = Acceleration time*

57 = Braking time*

( *SK 540E and above)

P547

Function Bus setpoint 2

(Function of bus setpoint 2)

up to SK 535E

S

P

0 ... 55

{ 0 }

This parameter is identical to P546.

P548

Function Bus setpoint 3

(Function of bus setpoint 3)

up to SK 535E

S

P

0 ... 55

{ 0 }

This parameter is identical to P546.

P552

[-01]

[-02]

CAN master circle

(CAN Master cycle time)

S

0 … 100 ms

{ all 0 }

SW1.6 and above

In this parameter, the cycle time for the CAN/CANopen master mode and the CANopen encoder
is set (see P503/514/515):

[-01] = CAN Master function, cycle time for CAN/CANopen Master functionality

[-02] = CANopen absolute encoder, cycle time of CANopen absolute encoder (SK 53xE)

According to the Baud rate set, there are different minimum values for the actual cycle time:

Baud rate

Minimum value t

Z

Default CAN Master

Default CANopen Abs.

10kBaud

10ms

50ms

20ms

20kBaud

10ms

25ms

20ms

50kBaud

5ms

10ms

10ms

100kBaud

2ms

5ms

5ms

125kBaud

2ms

5ms

5ms

250kBaud

1ms

5ms

2ms

500kBaud

1ms

5ms

2ms

1000kBaud:

1ms

5ms

2ms

The range of values which can be set is between 0 and 100ms.

With the setting 0 “Auto” the

default value (see table) is used. The monitoring function for the CANopen absolute value
encoder no longer triggers at 50ms, but rather at 150ms.