POSICON position control for NORD frequency inverters, SK 530E and above

56

Subject to technical alterations

BU 0510 GB-3911

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter set

P626

Relais Position

(Relay Position)

SK 530E and

above

S

-

50000,000 …

50000,000 rev.

{ 0,000 }

Comparative position for the settings 22, 23 and 25, 26 of relays 1 and 2 or outputs DOUT 1 and
DOUT 2, as well as for the Bus IO Out Bits.

NOTE:

For further information please refer to Sections 3.8.1 and 3.8.2

P630

Position slip error

(Position slip error)

SK 530E and

above

S

0,00 ... 99,99 rev.

{ 0,00 }

The permissible deviation between the estimated and the actual position can be adjusted. As
soon as a target position is reached, the estimated position is set to the current actual position.

If a value which is too low is selected, the error message "E14.5" "Position change and speed do
not match" can occur with slip error monitoring.

With a setting of "0" the slip error monitoring is disabled.

P631

Abs/Inc slip error

(Slip error absolute/incremental encoder)

SK 530E and

above

S

0,00 ... 99,99 rev.

{ 0,00 }

The permissible deviation /slip error between the absolute encoder and the incremental encoder
can be adjusted.

If a value which is too low is selected, the error message "E14.6" position change for absolute
and incremental encoder does not match" can occur for the slip error monitoring.

With a setting of "0" the slip error monitoring is disabled.

P640

Unit of position value

(Unit of position value)

SK 530E and

above

S

0,00 ... 99,99 rev.

{ 0,00 }

Setting the measurement units:

0:

Rev

(Rotations)

1:

°

(Degrees)

2:

rad

(Radians)

3:

mm

(Millimetres)

4:

cm

(Centimetres)

5:

dm

(Decimetres)

6:

m

(Metres)

7:

in

(Inch)

8:

ft

(Feet)

9:

(no unit)

NOTE: For further details please refer to Section 3.5