2 terminal blocks sk 54xe size 1, Terminal blocks sk 54xe size 1 – 4 – NORD Drivesystems BU0510 User Manual

Page 9

Advertising
background image

2 Encoder connection

BU 0510 GB-3911

Subject to technical alterations

9

2.1.2

Terminal blocks SK 54xE Size 1

– 4


X5: digital inputs and

voltage supply

R

i DIN

approx. 4.5k


with SK 540E

Terminal 42

internal

+15V max. 150mA

+5V max. 250mA

with SK 545E

Terminal 44

external

+18-30V min. 800mA

X6: Incremental encoder

input

Incremental encoder,

e.g.:

10-30V, TTL, RS422

2048 Imp./Rpm.

Note: 5V encoders should

not be used.

.

X7: additional digital inputs

and outputs

DIP switch:

Switching from analog

inputs AIN2/AIN1

current/voltage setpoint

I = current 0/4...20mA

V = voltage 0...10V

NOTE:

AIN2

– upper DIP Switch

AIN1

– lower DIP Switch

X8: VI_S 24V, input of the

pulse lock

VO_S 15/24V, output for

starting up without
safety switching unit

not with 115VAC devices

further details in

handbook BU 0530

X4: analog inputs and

outputs

+10V max. 5mA

0...10V or 0/4...20mA

Analog output

: 0 … 10V

X11:1x RJ12 socket to

connect the RS232
or RS485 interface

X9/X10: 2x RJ45 socket to

connect the
CAN/CANopen
interface

X14: Universal encoder

interface

Fig. 2: Terminal blocks, SK 54xE Size 1 - 4