NORD Drivesystems BU0510 User Manual

Page 53

Advertising
background image

4

Parameter settings

BU 0510 GB-3911

Subject to technical alterations

53

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter set

P607

[-01]

...

[-05]

Ratio

(Ratio)

SK 530E and

above

S

-65000 ... 65000

{ all 1 }

[-01] = Incremental encoder

[-02] = Absolute encoder

[-03] = Setpoint and actual values

[-04] = Universal encoder

[-05] = Synchronous operation

The speed ratio is set for incremental and absolute encoders.

This is also effective for synchronous control (Master- Slave, P610).

ratio

Reduction

Ratio

Speed

n

n

G

M

NOTE:

For further information please refer to section 3.5.

P608

[-01]

...

[-05]

Reduction Ratio

(Reduction Ratio)

SK 530E and

above

S

P

1 ... 65000

{ all 1 }

[-01] = Incremental encoder

[-02] = Absolute encoder

[-03] = Setpoint and actual values

[-04] = Universal encoder

[-05] = Synchronous operation

The speed reduction ratio is set for incremental and absolute encoders.

This is also effective for synchronous control (Master- Slave, P610).

ratio

Reduction

Ratio

Speed

n

n

G

M

NOTE: For further information please refer to Section 3.5.

P609

[-01]

...

[-03]

Offset Position

(Offset position)

SK 530E and

above

S

-

50000,000 …

50000,000 rev.

{ all 0 }

[-01] = Incremental encoder

[-02] = Absolute encoder (CANopen

[-03] = Universal encoder

Here, an independent offset value for absolute and relative position specifications

can be set for

all encoder systems used.