3 drying hopper, 4 installing the sight glass loader – Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual

Page 17

Advertising
background image

SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Page 17

3-3 Drying

Hopper

Removing the Rust Inhibitor

Rust preventative has been applied to internal unfinished surfaces. Remove rust inhibitor
before
using the drying hopper.

Using a non-water based degreasing agent, clean all inside surfaces of the drying hopper. Allow
components to dry thoroughly.

Inspect the inside of the drying hopper for loose connections, foreign objects, or a blocked
diffuser.

Air Trap Considerations

Sterling’s exclusive air trap assembly in the top of the drying hopper prevents ambient air from
contaminating the material being dried.

; Keep the material level at the mid point of the air trap for maximum efficiency.
; Use a hopper loader or vacuum conveying system to maintain the proper material level.

3-4 Installing the Sight Glass Loader

Levels A and C

; Sight glass loaders use flange mountings. See Figure 5 on Page 18 for sight glass flange

templates. You can mount the material receiver hopper directly to the processing machine by
cutting a hole in the machine bin lid and fastening the receiver to it. The material receiver
mounting flange mates with existing Sterling equipment and uses the same mounting holes as
previous Sterling models.

; Complete the vacuum and material tubing from the take-off tubes located on the SDAP cart.

See Section 3-6 on the following page for information on installing material/vacuum tubing.

; Connect the quick disconnect cable for the demand sensor to the SDAP cart. See Figure 9 on

Page 26 for more information.

Advertising