SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Page 19

; Vacuum leaks anywhere in the system reduce system capacity.
; Keep the number of material tube bends to a minimum for maximum system capacity.
; Use long radius tube bends on material lines.
; Keep the total footage of material conveying flex hose to a minimum. Long flex hose

material runs reduce system capacity.

; Support tubing about every ten feet with straps, pipe hangers, or brackets.
; Tube joints must be rigid to prevent vacuum or material leaks.

; Cut tube ends square and chamfer edges smooth. Use a fixed band saw or power miter

saw when making cuts. You can use a tubing cutter on aluminum tubing; for cutting stainless
steel, use a saw with a carbide or diamond-impregnated saw blade. Chamfer stainless steel
edge cuts with a die grinder or a hardened rasp file.

; Clean all tubing after cutting and before assembly. Run a rag dampened in a non-volatile

cleaning solvent through all tubing and couplers to remove sediment from shipping or
cutting. Run a quantity of low-grade material through new lines to remove any remaining
sediment, and discard the material immediately.

; Tube ends must butt together inside couplers.

; Tighten tube coupler nuts from the center outward to create a tight seal and allow proper

contact of the internal grounding strip.

; Each material tubing run must maintain a continuous ground through the tubing and

couplers, from pickup point to vacuum hopper. Ungrounded flexible hoses should have
ground wires wound around the outside
.

; If you must cut bends, cut the straight section and allow enough straight length for complete

insertion into a coupler.

; You can attach a quick-change or standard tube coupler to vinyl flex hose by inserting a stub

of hard tube into the hose and securing it with a hose clamp. Make sure that enough tube
extends from the hose to properly install the quick-change or coupler. Apply clear silicone
caulk around adjoining tube seams for exterior bolted couplers.

; If you use stainless flexible material hose, the material flow must be in the same direction as

the arrows on the hose. Material direction is not critical with vinyl flex hose.

Advertising