SDAP Series PD 2 to PD 4 Drying and Conveying Systems

4-15 Optional Seven Day Timer

The seven-day timer can be programmed for daily or weekly (over midnight) on/off operation.
An internal battery back up holds the settings in memory when the dryer is de-energized.

h

m

SHIFT

SET/RESET

DAY

PROG

OUT

CHECK

WRITE

TIME ADJ

P1
P2
RUN

AUTO

ON

OFF

OUT

1

2

COPY

CYCLE/PULSE

TIMER 1 2 MAN

PULSE 1 2 AUTO

MODE

BOOT

CLR

(1) SHIFT key
(2) SET/RESET key

(3) h key

(5) CHECK key

(12) OUT switch

(4) m key

(6) WRITE key

(11) MODE switch

(10) CLR key

(7) TIME ADJ key

(9) COPY key

(8) CYCLE/PULSE key

(13) TIMER/PULSE switch

(14) MAN/AUTO RESET switch

THU

MON

SUN

TUE WED

SAT

FRI

S
m

AM
P M

AM
PM

S
m

P M

AM

2

1

1
2

PM

AM

1

SUN

MON

P M

FRI

WED

TUE

THU

SAT

1

Day indicator

Cursor

Main display
Pulse width indicator

Indicator for number

of remaining steps

Set circuit

number indicator

Timing chart display

Time adjustment

mode indicator

Power failure indicator
Output circuit indicator

Display

Timer

(15) Output indicator

(16) Timing chart display

No. Function

1

Shifts the cursor (

∇) specifying a day to the right.

2

Sets or cancels (reset) a specified day.

3, 4

Sets a time or ON/OFF time width. (hours, minutes)

5

Monitors the parameters set for an operation during an operation.

6

Sets parameters. (Write)

7

Sets a time adjustment mode.

8

Specifies a cyclic operation, or sets a pulse width. (Not used)

9

Specifies a day substitution operation. (Copy)

10

Cancels the parameters set for each circuit, or a day substitution operation.

11

P1:

Circuit 1 programming mode.

P2:

Circuit 2 programming mode.

Run: Run

mode.

12

ON:

Turns on the output regardless of the program

AUTO: Executes according to the program.
OFF:

Turns off the output regardless of the program.

13

TIMER: Executes an ordinary timer or cyclic operation.
PULSE: Executes a pulse-output operation.

14

Specifies automatic or manual operation following a power failure.

15

The Output indicator will light when the timer output is energized. (Dryer On)

16

Displays the time at which the next operation will be preformed.