SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Figure 11

Typical SDAP Temperature Controller

PV

SV

OUT1

OUT2

MANU

STOP

RMT

AT

SUB1

AT

E5CK


4-8 Setting the Process Air Temperature

To change the process air temperature set point with the dryer running:

„ Press

to raise the set point to the temperature you want.

„ Press

to lower the set point to the temperature you want.

„ Press the

AT

Auto-tune key to initiate auto-tuning.

4-9 Setting the Shift on Dew Point

SDAP dryers shift air flow from the on-line desiccant bed to the regenerated desiccant bed,
based on actual dew point demand, not fixed time cycles. After the off-line bed regenerates, the
PLC controller waits for a high dew point signal from the process air dew point controller before
switching beds. The PLC controller has a four (4) -hour timer override if it does not receive a
signal from the dew point control.