Setting e5ck security in protect mode, Secr, Keyp – Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual

Page 58

Advertising
background image

Page 58

SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Figure 17

Display Readout for Mode Settings

PV

SV

SV

SV

SV

SV

SV

SV

Menu display

Level 0 mode

Level 1 mode

Level 2 mode

Setup mode

Expansion mode

Option mode

Calibration mode


Setting E5CK Security in Protect Mode

1. To access protect mode, press and hold the

AT

AT

key and the

display key for

more than one and a half to two (1.5 to 2) seconds.

2. The display should read

SECr

for security mode. If you press the

display key

for short presses you will toggle between (

SECr

) and (

KEYP

) for AT protect.

3. With the display reading

SECr

, set the security levels by the arrow up and down keys.

Change the security level to 1 to make changes to the operating parameters. The
temperature controller is factory set to Security Level 5, the dew point indicator is factory
set to Security Level 3.

Available Security Levels

Security

level

Mode

0 1 2 3 4 5 6

Calibration X
Option

X

X

Expansion

X

X

Setup

X

X

Level 2

X

X

X

Level

1

X X X X

Level

0

X X X X X X

Any mode marked with an X is displayed in the Security
Level indicated. To return to the main display (run mode),
press and hold the AT and display key for 1.5 to 2 seconds.