SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Page 43

Figure 15

Typical PD2-4 Electrical Schematic, Drawing 2

TYPE K

TYPE K

FOR JUMPER

TERMINALS

YELLOW

7-DAY TMR

(OPTIONAL ALARM)

ELECTRICAL UNIT

LEVEL SENSOR

LOW LEVEL SENSOR

DRYING HOPPER

(OPTIONAL)

4

4

4

C1 N O

SEE TIMING CHART

CONFIGURATIONS

FOR JUMPERS

TIMING INPUTS

DRYING HOPPER

DEMAND REED SW.

DRYING HOPPER

LOADING COMPLETE

CONVEYING

FOR TIMING

TERMINALS

DUMP DELAY

(OPTIONAL)

(OPTIONAL)

JUMPERS

YELLOW

18GA

4

4

6

DRYING HOPPER

CONVEY POWER ON

LOADING COMPLETE

MAHCINE LOADER

MACHINE LOADER

DEMAND PROX. SW.

MACHINE LOADER

(OPTIONAL)

POWER ON

4

4

6

4

4

(LINE 129)

4

REGEN TEMP ALARM

PUSH TO SILENCE

HIGH PROCESS

LOW COMPRESSED

HIGH LEFT BED

REGEN TEMP ALARM

HIGH RIGHT BED

TEMP ALARM

AIR ALARM

(LINE 136)

(LINE 129)

4

T2
T6
T4

T4

T6

T2

4

4

4

T3

(-)RED

(+)YEL

T5

T7

(-)RED

(+)YEL

T5

T3
T7

REGEN BLOWER

DEW POINT BED

PROCESS BLOWER

SWITCHING

ENABLE

ENABLE

INPUT

(LINE 139)

4

4

COMPRESSED AIR

DRYER ON/

SHUTDOWN

SEQUENCE

4

17

4

CONTACTOR

I/19

34

DRYING HOPPER"

"CRITICAL LEVEL

2

2

O/8

O/9

O/10

31

I/16

I/18

I/17

33

32

O/11

I/15

I/14

30

8

29

48

49

7

7

46

44

47

45

VAC/VDC

O/7

O/6

O/5

I/13

I/12

28

27

2

8

I/11

I/10

26

25

2

4

43

43

42

41

41

40

2

MACHINE LOADER

CONVEY TIMER

DRYING HOPPER

CONVEY TIMER

2

2

2

MACHINE LOADER
CONVEY BLOWER

"MATERIAL LOADING"

CONVEY BLOWER

DRYING HOPPER

"MATERIAL LOADING"

2

2

2

2

ALARM STROBE (OPTIONAL)

AUDIBLE ALARM (OPTIONAL)

"LEFT REGEN HEATER ON"

2

2

BED SHIFT RELAY

"RIGHT BED IN REGEN"

"HIGH REGEN TEMP"

2

2

2

2

GRD

I/1

2

O/4

VAC/VDC

VAC/VDC

O/3

O/2

5

I/9

I/8

I/7

24

9

I/6

I/5

23

TC

22

TC

39

40

4

39

37

4

38

VAC/VDC

O/1

O/0

VAC/VDC

I/4

AC COM

10

2

I/3

I/2

21

19

18

36

4

20

35

4

"RIGHT BED HEATER ON"

2

CONTACTOR

RIGHT REGEN HEATER

LEFT REGEN HEATER

2

2

CONTACTOR

PROCESS HEATER

"PROCESS HEATER ON"

2

2

2

CONTACTOR

"PROCESS BLOWER ON"

REGEN BLOWER

"REGEN BLOWER ON"

2

2

CONTACTOR

PROCESS BLOWER

2

L2/N

I/0

AC COM

16

6

2

L1

2

4

2

2

3MTR

3RS

1TMR

2MTR

4RS-LT

EU

2LS

4

31

32

33

1LS

5RS-LT

G

1PRS

G

2M

1M

2RS

1C

15LT

R

1CR

12LT

W

1AH

13LT

G

3M

4M

14LT

G

2TMR

3TMR

11LT

R

10LT

G

9LT

G

30L

40L

GROUND

3C

7LT

G

8LT

G

2M

1M

5LT

G

2C

8LT

G

1SSR

20L

10L

These schematics are for reference only. Refer to the electrical schematic in your Customer Information Packet.