9 drying hopper loader, Levels b and c – Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual

Page 22

Advertising
background image

Page 22

SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Figure 6

Machine Loader Dry Air Closed Loop Take-Off Compartment

Indicator

knob

Adjustable

inner tube

Outer

tube

Hose

from

blower

Material

outlet

Hold-down

screw

FCO-1.5MD

3-8 Adjusting Sight Glass Proximity Sensor

Sensitivity

You can adjust the sensitivity of the material level proximity sensor in the sight glass. The
factory setting is correct for most applications. The sensor is factory-installed to the frame;
however, you should install the sensor at the material level height you want.

When adjusting, fill the glass and verify that the sensor detects your material. The LED on the
switch goes out
when it detects material.

„ For increased sensitivity, turn the potentiometer clockwise.
„ For decreased sensitivity, turn the potentiometer counterclockwise.

3-9 Drying Hopper Loader

Levels B and C

; The drying hopper loader may have been shipped loose. Mount the drying hopper loader to

top cover of drying hopper. The drying cover has the appropriate bolt holes supplied to
mount the vacuum hopper. See Section 3-5 on Page 18 for mounting tips.