Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual

Page 40

Advertising
background image

Page 40

SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Alarm Horn Output (O/7)

Optional

The

Alarm Horn Strobe Output

indicates a high process temperature condition and optional

critical low level at the drying hopper.

Machine Loader Convey Blower (O/8)

When

ON

, the

Machine Loader

convey blower contactor is energized.


Drying Hopper Convey Blower (O/9)

Optional

When

ON

, the

Drying Hopper

convey blower contactor is energized.

Machine Loader Convey Timer (O/10)

When

ON,

the convey timer starts timing a loading process.


Drying Hopper Convey Timer (O/11)

Optional

When

ON,

the convey timer starts timing a loading process.


Status LED Indicators

Power

The

Power

indicator lights when the PLC receives 115V control power.


Run

The

Run

indicator lights when the PLC executes the program in normal conditions.


Fault

The

Fault

indicator lights when the PLC program has a problem or failure condition.


Force

The

Force

indicator is not used.