SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Page 59

Entering Operating Parameters to Select Modes

To enter the menu display:

1. Press

for one second (keep the pressure on the button for about 1.5 to 2 seconds).

The screen displays

.

2. Press the

Up Arrow key to toggle through the different modes.

The

SV

readout displays the mode you selected.

3. To switch parameters within a mode, press the

Display key once more for about

one and a half to two (1.5 to 2) seconds.

The

PV

readout displays the different parameters within each mode.

4. Use short presses on the

Display key to display each parameter within a mode.

The

SV

readout displays the different values for the parameter within a mode.

5. Press

and

to set the higher or lower the values of a parameter.

6. Press

for about one and a half to two (1.5 to 2) seconds to move up a level back

into the different modes.

7. Press

until Level 0 displays.

8. Press

for about one to one and a half (1 to 1.5) seconds to go to Operating mode.

Factory Settings E5CK for Process Temperature

1. Remove controller from housing and check for output board number E53-QR4R (Pulse

NPN/Relay).

2. Make sure jumper setting for input type is set for thermocouple

TC-PT

, middle jumper.

3. Return controller to housing.

4. Press the

Display key for one (1) second to enter Menu Display.

5. Press the

Arrow Up key to get to Setup mode.

6. To switch parameters within Setup mode, press the

Display key.