SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Page 33

OUT1 - Lit when control output 1 turns on.

The

OUT

indicator lights when the controller signals the process heaters to be energized.


OUT2 - Lit when control output 2 turns on.

Not used in this application.

MANU - Lit when the manual operation mode is being used.


STOP - Lit when control operation has been stopped.

Not used in this application.

RMT - Lit during remote operation.

Not used in this application.

AT - Flashes during auto-tuning.

SUB1 Lit when the output function assigned to auxiliary output 1 turns on.

The

SUB1

indicator lights when the process temperature exceeds the set point temperature by

more than the alarm deviation value. This alarm output de-energizes the heaters. Heaters re-
energize when the temperature falls within the acceptable range.

4-7 Identifying Temperature Controller Keys

Display Key

This key shifts the display to the next set of parameters. Then, the menu screen displays.

Down Key

The Down arrow key lets you lower the process air set point temperature. During setup, it lets
you decrease the value of the parameter displayed on the set point LED readout.

Up Key

The Up arrow key lets you raise the process air set point temperature. During setup, it lets you
increase the value of the parameter displayed on the set point LED readout.

AT

Auto-Tune Key

Hold down for two seconds to initiate auto-tune. Repeat to cancel.