HP XP Continuous Access Software User Manual

Page 102

Advertising
background image

Table 27 Logical path status

Remarks

Status

This path was successfully established and can be used for
XP Continuous Access Journal remote copy activities.

Normal

An operation for configuring or deleting this logical path
is in progress.

Nothing

An error occurred with the initialization of the connection
between the local and remote array. Probable causes are:

No cable is connected to the local array.

No cable is connected to the remote array.

No cable is connected to the network device that comes
between the local and remote arrays.

Initialization Failed

This status indicates one of the following:

A timeout error occurred between the primary and
secondary arrays.

A logic error was detected between the primary and
secondary arrays.

Communication Time Out

The local array rejected the function for configuring logical
path connection. All logical path resources in the local
array might be used for other connections.

Resource Shortage (Port)

The remote array rejected the function for configuring
logical path connection. All logical path resources in the
remote array might be used for other connections.

Resource Shortage (Pair-Port)

The serial number of the array connected to this logical
path does not match the serial number specified by the
Add DKC pane.

Serial Number Mismatch

The port is not an initiator port.

Invalid Port

This status indicates one of the following:

The specified port number is incorrect.

The port in the remote array is physically disconnected
from the local array.

Pair-Port Number Mismatch

The port on the remote array is not an RCU target port.

Pair-Port Type Mismatch

A communication timeout error has occurred on the path
between the primary and secondary arrays.

Communication Failed

Removing the relationship between primary and secondary arrays

To remove the relationship between primary and secondary arrays and remove all logical paths
between the two arrays, the primary and secondary array administrators must perform the following
procedure:

1.

Ensure that all affected XP Continuous Access Journal volume pairs have been deleted.

2.

Ensure that XP Command View Advanced Edition Software or XP Remote Web Console is in
Modify mode. For more information, see the HP StorageWorks XP Command View user guide
for XP Disk Arrays
or the HP StorageWorks XP Remote Web Console user guide for
XP12000/XP10000/SVS200
.

3.

Display the DKC Operation pane.

4.

In the Switch Display box, select DKC.

5.

Select Subsystem from the tree. The list displays remote arrays.

6.

Select and right-click the remote arrays from the list.

102 Configuring arrays and logical paths

Advertising
This manual is related to the following products: