HP XP Continuous Access Software User Manual

Page 181

Advertising
background image

Table 50 Example of XP RAID Manager configuration definition file at secondary site (instance 16)

HORCM_MON

#ip_address service poll(10ms) timeout(10ms)

123.456.80.51 20331 1000 3000

HORCM_CMD

#dev_name dev_name dev_name

#UnitID 0 (Serial# 62490)

/dev/sdf

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

# /dev/sdt SER = 62486 LDEV = 10 [ FIBRE FCTBL = 3 ]

VG_TC VG_032 CL1-A-1 0 10

# /dev/sdu SER = 62486 LDEV = 64 [ FIBRE FCTBL = 3 ]

VG_TC VG_033 CL1-A-1 0 11

# /dev/sdv SER = 62486 LDEV = 12 [ FIBRE FCTBL = 3 ]

VG_TC VG_034 CL1-A-1 0 12

# /dev/sdw SER = 62486 LDEV = 66 [ FIBRE FCTBL = 3 ]

VG_TC VG_035 CL1-A-1 0 13

# /dev/sdt SER = 62486 LDEV = 10 [ FIBRE FCTBL = 3 ]

VG_SI VG_014 CL1-A-1 0 10

# /dev/sdu SER = 62486 LDEV = 64 [ FIBRE FCTBL = 3 ]

VG_SI VG_015 CL1-A-1 0 11

# /dev/sdv SER = 62486 LDEV = 12 [ FIBRE FCTBL = 3 ]

VG_SI VG_015 CL1-A-1 0 12

# /dev/sdw SER = 62486 LDEV = 66 [ FIBRE FCTBL = 3 ]

VG_SI VG_016 CL1-A-1 0 13

HORCM_INST

#dev_group ip_address service

VG_TC 123.456.78.51 20331

VG_TC 123.456.78.115 20331

VG_SI 123.456.80.51 20332

VG_SI 123.456.80.115 20332

Preparing for XP Continuous Access Journal operations

181

Advertising