NOTE:

If you select Yes and the metadata or journal data is full, update I/Os might stop.

NOTE:

Secondary array administrators cannot change this option.

Data Overflow Watch (0 to 600 sec): Time (in seconds) for monitoring whether metadata and
journal data are full. This value must be within the range of 0 to 600 seconds.

NOTE:

If Inflow Control is No, Data Overflow Watch does not take effect and does not

display anything.

Copy Pace: Pace (speed) for an initial copy activity for one volume. The default is Low.

Low: Speed of initial copy activity is slower than Medium and High.

Medium: Speed of initial copy activity is faster than Low and slower than High.

To specify Medium, ensure that the amount of update I/Os (that is, write requests from
hosts to primary data volumes) is 10 MB/s or less per parity group. If it exceeds 10 MB/s,
data volume pairs might become split (suspended).

High: Speed of initial copy activity is faster than Low and Medium.

To specify High, ensure that update I/Os (that is, write requests from hosts to primary
data volumes) do not occur. If update I/Os occur, data volume pairs might become split
(suspended).

NOTE:

Secondary array administrators cannot specify this option.

Unit of Path Watch Time: Allows you to specify the unit of path watch time. You can specify
one of the following: minute, hour, or day.