Show properties command, Show system command – HP EVA Array iSCSI Connectivity Option User Manual

Page 161

Advertising
background image

Authority

None

Syntax

show perf

Examples

The following is an example of the show perf command:

mpx100 #> show perf

WARNING: Valid data is only displayed for port(s) that are not

associated with any configured FCIP routes.

Port Bytes/s Bytes/s Bytes/s Bytes/s Bytes/s

Number (init_r) (init_w) (tgt_r) (tgt_w) (total)

—— ——– ——– ——– ——– ——–

GE1

0

0

0

27K

27K

GE2

0

0

0

0

0

FC1

0

0

0

0

0

FC2

0

27K

0

0

27K

Show Properties command

Displays the values of both the Inactivity Timer and the CLI Prompt name.

Authority

None

Syntax

show properties

Examples

The following is an example of the show properties command:

mpx100 #> show properties

CLI Properties

—————-

Inactivty Timer 15 minutes

Prompt String

mpx100

Show System command

Displays the mpx100/100b product information, including serial number, software and hardware

versions, configuration, and temperature.

Authority

None

Syntax

show system

Examples

The following is an example of the show system command:

mpx100 #> show system

System Information

——————–

Product Name

HP StorageWorks mpx100

Symbolic Name

Rack3

System Mode

iSCSI Server Connectivity Mode

Serial Number

0539A01070

HW Version

2

SW Version

1.0.5.0

No. of FC Ports

2

No. of iSCSI Ports

2

Log Level

0

Log Length (KB)

32768

Temperature (c)

32