Hp storageworks eva storage system software, 7 eva configuration table (mpx100/100b), Table 7 – HP EVA Array iSCSI Connectivity Option User Manual

Page 35

Advertising
background image

Table 7 EVA configuration table (mpx100/100b)

EVA array

Operating

system

Software

version

One

mpx100

Second

mpx100

1

Fabric

attach

mpx100

Direct

connect

mpx100

Microsoft

Windows

XCS 6.100

nl

or later, XCS

09000000

or later

Apple Mac

OS X

XCS 6.100

nl

or later, XCS

09000000

or later

Not

supported

EVA4x00/

6x00/8x00

HP

OpenVMS

XCS 6.100

nl

or later,

nl

XCS

09000000

or later

(mpx100

only)

Not

supported

Microsoft

Windows

VCS 4.001

nl

or later

Apple Mac

OS X

VCS 4.001

or later

Not

supported

Not

supported

EVA3000/

5000

HP

OpenVMS

VCS 4.001

nl

or later

Not

supported

Sun Solaris

XCS 6.100

nl

or later, XCS

09000000

or later

EVA4x00/

6x00/8x00

VMware ESX

XCS 6.100

or later),

nl

XCS

09001000

or later

1

For configurations that include both single-path and multipath operating systems, single-path operating systems are supported

for single-path attachment on either (but not both) multipath mpx100s.

An EVA storage system configuration is considered to have two redundant HSV controllers. The following

list details the limitations of an EVA storage system by failover mode configuration:

In a fabric connect configuration, a maximum of two mpx100's/100b's can be zoned with one

EVA storage system.

In a fabric connect configuration, a maximum of one EVA storage system can be zoned with a

maximum of two mpx100's/100b's.

In a direct connect configuration, a maximum of two mpx100's/100b's are supported to one

EVA storage system.

An EVA storage system can present LUNs to iSCSI Initiators and Fibre Channel hosts concurrently.

HP StorageWorks EVA storage system software

The EVA iSCSI connectivity option is supported with current EVA storage software applications such as

HP StorageWorks Continuous Access, Business Copy, SSSU, and Replication Solutions Manager. There

are some restrictions with iSCSI hosts when using the EVA iSCSI connectivity option, as described in

the following sections.

EVA iSCSI connectivity user guide

35