Power-on self-test diagnostics

The mpx100/100b performs a series of tests as part of its power-on procedure. The POST diagnostic

program performs the following tests:

Memory

FLASH validation

PCI device discovery

Management Ethernet port

Heartbeat LED blink patterns

The Heartbeat LED indicates the operational status of the mpx100/100b. When the POST completes with

no errors, the Heartbeat LED blinks at a steady rate of once per second. When the mpx100/100b is in

maintenance mode, the Heartbeat LED illuminates continuously. The blink patterns that indicate critical

errors are described in the following sections. In addition to producing a Heartbeat error blink pattern, a

critical error also illuminates the System Fault LED.
The Heartbeat LED shows an error blink pattern for the following conditions:

1 blink—Normal operation

2 blinks—Not used

3 blinks—System error

4 blinks—Management port IP address conflict

5 blinks—Over temperature

Normal heartbeat blink pattern

A blink pattern of one second ON followed by one second OFF indicates that the mpx100/100b

is operating normally (see

Figure 72

).

Figure 72 Normal heartbeat blink pattern

System error blink pattern

A system error is indicated with a three-blink pattern (see

Figure 73

).

Figure 73 System error blink pattern

Management port IP address conflict blink pattern

An IP address conflict on the management Ethernet port is indicated with a four-blink pattern (see

Figure 74

).

174

Diagnostics and troubleshooting