Initiator rules and guidelines, Iscsi initiator rules and guidelines, Vmware iscsi initiator rules and guidelines – HP EVA Array iSCSI Connectivity Option User Manual

Page 31: Network teaming, Iscsi initiator software

Advertising
background image

Initiator rules and guidelines

This section describes the following iSCSI Initiator rules and guidelines:

iSCSI Initiator rules and guidelines

” on page 31

VMware iSCSI Initiator rules and guidelines

” on page 31

Windows iSCSI Initiator rules and guidelines

” on page 32

OpenVMS iSCSI Initiator rules and guidelines

” on page 33

Apple Mac OS X iSCSI Initiator rules and guidelines

” on page 32

Linux iSCSI Initiator rules and guidelines

” on page 32

Solaris iSCSI Initiator rules and guidelines

” on page 33

iSCSI Initiator rules and guidelines

This section describes iSCSI Initiator rules and guidelines.

iSCSI Initiators and mpx100/100b iSCSI ports can reside in different IP subnets. This requires set-

ting the mpx100/100b iSCSI gateway feature. See

Configuring the mpx100/100b

” on page 49

and

Command line interface

” on page 141 for more information.

There can be a maximum of eight mpx100/100b iSCSI targets per iSCSI Initiator.

Both single path and multipath initiators are supported on the same mpx100/100b.

Fibre Channel LUNs and iSCSI LUNs are not supported on the same server.

VMware iSCSI Initiator rules and guidelines

Supports:

Native iSCSI software initiator in VMware ESX 3.5

Guest OS SCSI Controller, LSI Logic and/or BUS Logic (BUS Logic only with SUSE Linux)

ESX server's native multipath solution, based on NIC teaming in the server

Guest OS boot from mpx100/100b iSCSI device

VMFS file system data stores and raw device mapping for guest OS virtual machines

Multi-initiator access to the same LUN via VMFS cluster file system

VMware ESX server 3.5 supports multipath, using ESX server's native multipath solution based

on NIC teaming

Does not support:

Hardware iSCSI HBA

BUS Logic Guest OS SCSI controller with Windows and/or Red Hat Linux

EVA3000/5000

Supported by the EVA iSCSI option with VMware:

NIC teaming

VMware native iSCSI software initiator.

See

Installing and upgrading EVA iSCSI connectivity

” on page 39.

Network teaming

The EVA iSCSI option supports NIC teaming with VMware.

iSCSI Initiator software

The EVA iSCSI option supports the VMware native iSCSI software Initiator. See

Installing and upgrading EVA iSCSI connectivity

” on page 39 for information on version support.

EVA iSCSI connectivity user guide

31

Advertising