37 chap bidirectional and bidirectional settings – HP EVA Array iSCSI Connectivity Option User Manual

Page 211

Advertising
background image

k.

Select the CHAP Login Information check box.

l.

Enter the CHAP secret for the mpx100/100b discovered iSCSI Initiator in the Target Secret

box. For example:
CHAPsecret01

m.

Select the Mutual Authentication check box.

n.

Click OK.

o.

Click OK and the initiator completes normal login.

Enabling bidirectional CHAP during discovery and

bidirectional CHAP during normal session

Table 37

lists the parameters you need to enable bi–directional CHAP during discovery and bidirectional

CHAP during normal session.

Table 37 CHAP bidirectional and bidirectional settings

mpx100/100b secret settings

MS Initiator secret settings

iSCSI Port

hpstorageworks

General Tab Secret

Hpstorageworks

Discovered iSCSI

Initiator

CHAPsecret01

Add Target Portal

CHAPsecret01

iSCSI Presented Target

hpstorageworks

Log on to Target

CHAPsecret01

NOTE:

These are examples of secret settings. You must configure CHAP with settings that apply to your

specific network environment.

1.

Enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry. Select one of the following

procedures, depending upon the interface you are using:

a.

To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using HP

StorageWorks mpx Manager:
• If the iSCSI Initiator is not listed under Discovered iSCSI Initiators:

i.

Go to the Wizard menu and select the Add Initiator Wizard and enter the iqn

name.

ii.

Select the Enable CHAP check box.

iii.

Enter a CHAP secret. For example:
CHAPsecret01

• If the iSCSI Initiator is already listed under Discovered iSCSI Initiators:

i.

Select the Initiator in the left-hand column of the Discovered ISCSI Initiator list.

ii.

Click the Information tab.

iii.

Select the Enable CHAP check box.

iv.

Enter a CHAP secret. For example:
CHAPsecret01

b.

To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using the

mpx100/100b CLI:
• If the iSCSI Initiator is not listed under the Show Initiators command:

i.

Enter the initiator add command and add the iSCSI Initiator that is about to

do discovery.

ii.

Enable CHAP and enter a CHAP secret. For example:
CHAPsecret01

• If the iSCSI Initiator is already listed under the Show Initiators command:

i.

Enter the initiator mod command and select the iSCSI Initiator that is about to

do discovery.

EVA iSCSI connectivity user guide