HP EVA Array iSCSI Connectivity Option User Manual

Page 206

Advertising
background image

ii.

Enter the IP address of the iSCSI port of the mpx100/100b.

iii.

Click Advanced.

iv.

Select the CHAP Login Information check box.

v.

Enter the CHAP secret for the mpx100/100b discovered iSCSI Initiator in the Target

Secret box. For example:
CHAPsecret01

See

CHAP restrictions

” on page 203 for more information on CHAP.

vi.

Click OK and the initiator completes Target discovery.

• Using iSNS for target discovery:

i.

Click Add under iSNS Servers.

ii.

Enter the IP address of the iSNS server.

iii.

Click OK.

b.

Click Targets.

c.

Select the appropriate target for login.

d.

Click Log On.

e.

Click Advanced.

f.

Select the CHAP Login Information check box.

g.

Enter the CHAP secret for the mpx100/100b discovered iSCSI Initiator in the Target Secret

box.

h.

Click OK.

i.

Click OK and the initiator completes normal login.

Enabling CHAP for the mpx100/100b-discovered iSCSI initiator entry

To enable CHAP for the mpx100/100b-discovered iSCSI initiator entry using the HP StorageWorks

mpx Manager

If the iSCSI initiator is not listed under Discovered iSCSI Initiators:

1.

Go to the Wizard menu and select the Add Initiator Wizard and enter the iqn name string.

2.

Select the Enable CHAP checkbox.

3.

Enter a CHAP secret, for example, CHAPsecret01.

If the iSCSI initiator is already listed under Discovered iSCSI Initiators:

1.

Select the initiator in the left-hand column of the Discovered iSCSI Initiator list.

2.

Select the Information tab.

3.

Select the Enable CHAP checkbox.

4.

Enter a CHAP secret, for example, CHAPsecret01.

To enable CHAP for the mpx100/100b–Discovered iSCSI Initiator entry using the mpx100/100b CLI:

If the iSCSI initiator is not listed under the show initiators command:

1.

Issue the initiator add command and add the iSCSI initiator that is about to do discovery.

2.

Enable CHAP and enter a CHAP secret, for example CHAPsecret01.

If the iSCSI initiator is already listed under the show initiators command:

1.

Issue the initiator mod command and select the iSCSI initiator that is to do discovery.

2.

Enable CHAP and enter a CHAP secret, for example CHAPsecret01.

206

Setting up authentication

Advertising