Table 89 Hardware Setting Items (Cnt Ac-J Z ATTIME Suspend)

Remarks

Description

Item

Before performing copy operations, this
item must be set by using the Remote
Web Console.

A journal group is required for each of
the primary and secondary sites.

Timer type: System

Journal group

At least one journal volume is required
for each journal group.

Journal volume

Before performing copy operations, this
item must be set by using Remote Web
Console.

Set this for the secondary site.

BC Z C/T group ID

This item must be set if the Remote DKC
Control Function is to be used.

Command device

For the route in the forward direction
(Primary

→ Secondary)

This is required when a reverse direction
command device uses the Remote DKC

For the route in the reverse direction
(Secondary

→ Primary) (optional)

Control Function to operate a primary
site storage system from a secondary site.

An inter-DKC logical path (bidirectional)
must be established between the primary
and secondary sites.

Logical path

Preparing the software (Cnt Ac-J Z ATTIME Suspend)

Table 90 (page 285)

lists the software settings for using Business Continuity Manager in the Cnt

Ac-J Z ATTIME suspend function.

Table 90 Software Setting Items (Cnt Ac-J Z ATTIME Suspend)

Remarks

Description

Item

Disk configuration definition files are
required at the primary site and
secondary site.

Disk configuration definition file

This item is not necessary if you use
Remote Web Console to set up logical
paths.

An inter-disk controller logical path
(bidirectional) between the primary
site and the secondary site must be
defined.

Path set definition files

Set this item before starting a copy
operation.

Forward and reverse direction routes

Route list definition file and command
device definition file

The forward route is required when you
operate the secondary site storage
systems from the primary site by using
the Remote DKC Control Function. The
reverse route is required when you
operate the primary site storage systems
from the secondary site by using the
Remote DKC Control Function.

Defining a configuration so that the Cnt Ac-J Z ATTIME Suspend function can be used 285