HP XP P9500 Storage User Manual

Page 717

Advertising
background image

When information obtained from Business Continuity Manager agent is not updated

Table 124 (page 717)

lists the events and actions to be taken when information is acquired by

Command View Advanced Edition Software, when information from Business Continuity Manager
agent is not updated. Locate (in the Event column, going down in the order listed) the first description
that matches the event that occurred, and then take the relevant action (in the Action column) to
solve the problem.

Table 124 Events and actions to be taken when information from Business Continuity Manager
agent is not updated

Action

Event

The specified port number is in use. Either terminate the
program that is using the port number or change the port

The following message is displayed: YKY330I SOCKET
API FAILURE (OPEN,BIND,-0000001,0000048)

number in the initialization parameter, and then restart
Business Continuity Manager agent.

Protected by RACF. Check, and, if necessary, revise the
RACF settings and then restart Business Continuity Manager
agent.

The following message is displayed: YKY330I SOCKET
API FAILURE (INIT,INITAPI,-0000001,0000156)

Protected by RACF. Check, and, if necessary, revise the
RACF settings and then restart Business Continuity Manager
agent.

The following message is displayed: YKY330I SOCKET
API FAILURE (OPEN,BIND,-0000001,0000013)

Make sure that the user SVC has been registered and then
restart Business Continuity Manager agent.

Business Continuity Manager agent has terminated
abnormally with a system completion code (Fnn). (Fnn:
SVC number)

Take appropriate action according to the displayed
message.

An error message is displayed on the console or in
SYSLOG

.

Error types and error information handling