HP XP P9500 Storage User Manual

Page 349

Advertising
background image

7.

From the primary host, make sure that the Cnt Ac-S Z copy group status is SWAPPING, and
then execute the YKRESYNC FORWARD command for the Cnt Ac-S Z copy group.

8.

Transfer the application information to the primary site.

Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration

The following table explains how to perform maintenance for a 3DC Cascade (Cnt Ac-J Z x Cnt
Ac-J Z) configuration and how to take action if a failure occurs.

Table 105 Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration

See:

Description

Target

Maintenance
or failure

No.

“Performing
primary

Suspend the Continuous Access Journal Z copy pair between the primary
site and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate

→ Remote).

Primary site storage
system maintenance

Maintenance

1

site
storage
system

Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration 349

Advertising